Use, Care,
& Maintenance
Adscope Stethoscope
®
Thank you for choosing an ADC
®
ADSCOPE
TM
Stethoscope. Your new ADC
®
ADSCOPE
TM
stethoscope is designed to provide unsurpassed acoustic sensitivity,
unrivalled durability, and unparralleled comfort. Every component has been care-
fully designed to maximize performance.
Device Description and Intended Use
This device is intended for medical diagnostic purposes only. It can be used for
listening to heart, lung and other body sounds as well as for normal auscultation.
The device is not designed, sold or intended for use except as indicated.
General Warnings
A warning statement in this manual identifies a condition or practice
which, if not corrected or discontinued immediately, could lead to
patient injury, illness, or death.
CAUTION:
Never use stethoscope without eartips firmly locked in place.
WARNING:
This product may contain a chemical known to the state of California to
cause cancer, birth defects, or other reproductive harm.
Selection of the Chestpiece (AFD Models - 600, 603, 612, 614, 615)
The ADC
®
ADSCOPEs
TM
with AFD Technology provide the enhanced acoustic
response of a traditional bell and diaphragm in a convenient one-sided chest-
piece. A rubber gasket around the perimeter of the diaphragm allows you to alter
the frequency response by changing the contact pressure.
Selection of the (Traditional 2-sided model) Combination
Chestpiece
On ADC
®
ADSCOPE
combination stethoscopes you can
select the use of either the diaphragm for monitoring high
frequency sounds, or the open bell for monitoring low
frequency response.
To select a side, hold the chestpiece valve stem in one
hand and rotate the chestpiece 180° with the other hand
until it “clicks” into place. The stem has a slight bend,
the high point of the bend faces the activated side.
To confirm which side is activated, tap lightly on one
side, then the other, to hear which provides the positive response.
Converting the Chestpiece (601 Only)
The #601 chestpiece drum accommodates 2 different
chestpiece attachments of your choice. To attach the
bell you must first remove the pediatric diaphragm
and then thread the bell clockwise until tight.
To remove pediatric diaphragm twist in
a counterclockwise direction.
Orientation of the Headset
The binaurals (eartubes) are angled at 15° to
permit a comfortable, acoustically sealed aural
fit. Eartips should point forward, towards the
bridge of the nose to fit properly.
Adjusting the Spring Tension in the Headset
To reduce the tension, grip the binaurals firmly using both hands with fingers at
the center of the “Y” in the tubing,
thumbs at each side where the tubing
branches out. Flex bin
aurals gradually
until the desired tension is obtained.
To increase the tension, grip the binaurals
in the hand and squeeze the binaural
tubes together gradually.
CAUTION: Excessive adjustment could
weaken the spring.
!
(Fig. 1)
(Fig. 2)
Correct
For low frequency response (bell phase)
simply hold the chestpiece in place with
light pressure. (Fig. 1)
For high frequency monitoring (diaphragm
phase) apply firm fingertip pressure on the
sculpted finger rest. (Fig. 2)
Incorrect
TO: reduce tension
TO: increase tension
Diaphragm Activated
Bell Activated
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - Adscope™ Stethoscope

Use, Care,& MaintenanceAdscope™ Stethoscope®Thank you for choosing an ADC®ADSCOPETMStethoscope. Your new ADC®ADSCOPETMstethoscope is desi

Seite 2 - Care and Maintenance

Shortening the Tube Length (Non Cardiology Models ONLY)All ADSCOPES™(except #600 Platinum Cardiology,#601 Convertible Cardiology and#602 Cardiology mo

Kommentare zu diesen Handbüchern

Keine Kommentare